Thib ob -theem biological Safety txee tswj cov txheej txheem
1. Cov khoom siv yuav tsum tau muab tso rau hauv ib puag ncig uas muaj qhov dej ntws ntawm 10-300C thiab cov av noo txheeb ze ntawm<>
2. Thaum lub tshuab hluav taws xob kev nyab xeeb thib ob ua haujlwm, lub qhov rooj iav tsis tuaj yeem tshaj qhov cim ntawm sab laug thiab sab xis iav qhov rooj npog.
3. Kev saib xyuas niaj hnub tsuas yog yuav tsum tau tshuaj tua kab mob thiab ntxuav lub studio, tshuaj tua kab mob thiab ntxuav lub vaj huam sib luag ua haujlwm nrog cov tshuaj chlorine- muaj cov tshuaj tua kab mob, thiab siv lub tshuab ntxhua khaub ncaws kom huv si los ntxuav qhov chaw sab nrauv thiab iav ntawm lub thawv, thiab khaws cov ntaub ntawv rau ntawm tsawg kawg yog 2 xyoos.
4. Siv cov tshuaj ntxuav tes kom tshem tawm cov plua plav tawm ntawm txhua qhov chaw sab nrauv thiab tshuaj tua kab mob hauv cov khoom siv txhua lub hlis, thiab khaws cov ntaub ntawv kom tsawg kawg 2 xyoos.
5. Tsis tu ncua (feem ntau ib xyoos ib zaug) sim qhov ntsuas tsis tu ncua ntawm ultra-chaw ua haujlwm huv, thiab khaws cov ntaub ntawv tsawg kawg 2 xyoos.

Cov lus qhia rau kev ntxuav thiab tshuaj tua kab mob ntawm cov khoom siv tshuaj lom neeg thib ob:
Txij li qhov nruab nrab seem yuav ua rau muaj kev loj hlob thiab kev loj hlob ntawm cov kab mob, thaum kawg ntawm qhov kev sim, tag nrho cov khoom nyob rau hauv lub thib ob biological kev ruaj ntseg txee nrog rau cov twj paj nruag thiab cov cuab yeej yuav tsum tau muab tshem tawm ntawm qhov chaw paug thiab tshem tawm los ntawm lub txee ruaj ntseg.
2. Before and after each use, remove the contamination on the inner surface of the secondary biological safety cabinet. Work surfaces and interior walls should be wiped down with a disinfectant that kills any microorganisms that may be found in the cabinet. At the end of each day's experiment, the work surface, the surrounding area, and the inside and outside of the glass of the secondary biological safety cabinet should be wiped to remove surface contamination. When effective against the target organism, a bleach solution or 70 percent alcohol can be used for disinfection. After using aggressive disinfectants such as bleach, it must be wiped again with sterile water.
Secondary biosafety txee yog biosafety tiv thaiv cov cuab yeej siv hauv microbiology, biomedical, biosafety laboratories thiab lwm lub chaw kuaj mob. Nws siv cov cuab yeej ua kom huv huv huv thiab tsis zoo lub thawv tsim los tiv thaiv ib puag ncig, cov neeg ua haujlwm thiab cov qauv, tiv thaiv kev sib kis ntawm cov teeb meem raug tshem tawm thiab cov aerosols, thiab muab kev nyab xeeb rau cov neeg ua haujlwm, kuaj thiab hla - kis ntawm cov qauv thiab ib puag ncig . Kev tiv thaiv yog cov cuab yeej tiv thaiv kev nyab xeeb yooj yim hauv chav kuaj biosafety qib tiv thaiv kab mob. Cov qauv bracket yog saws, thiab lub bracket thiab lub thawv tuaj yeem sib cais, uas yooj yim rau kev tuav thiab tso.